 The Best Relaytion
D2n Relay
108-98007 Rev. C EC-JM00-0009-03 ECOC: JM10 1. Apr. 04
D2n Relay
2 pole telecom relay, non-polarized, Through Hole Type (THT) Relay types: Features
- Standard DIL relay
V23105
non-latching with 1 coil
- Dimensions 20.3 x 10.1 x 10.43 mm, 0.800 x 0.400 x 0.450 inch - Switching and continous current 3 A - 2 changeover contacts (2 form C / DPDT) - Single contacts - Immersion cleanable - Four different coil sensitivities (150, 200, 400, > 500 mW) - Surge voltage resistance meets FCC Part 68 requirement: 1.5 kV (10 / 160 sec) between coil and contacts
Typical applications
- Communications equipment - Office equipment - Measurement and control equipment - Entertainment electronics - Medical Equipment - Consumer electronics
European Directive conformance:
UL 508 File No. E 111441 D2n relay product conformance according to: Directive 2000/53/EC: ELV (End of Life of Vehicles) Directive 2002/95/EC: ROHS (Restrictions of the use of certain hazardous substances in electrical and electronic equipment) Compliance is evidenced by written declaration from all raw material suppliers. Tyco Electronics AXICOM only has responsibility for the proper processing of these materials. Confirmation is valid for date codes 0418
Page 2 (11)
108-98007 Rev. C
D2n Relay
THT Version
V23105
Dimensions
V23105-A5xxx-A201
THT
mm
L W H T Tw S 20.2 0.1 10.0 0.1 11.43 0.2 3.5 0.3 0.72 - 0.2 0.3 0.1
inch
0.795 0.004 0.394 0.004 0.450 - 0.008 0.138 0.012 0.028 - 0.008 0.012 0.004
Mounting hole layout
View onto the component side of the PCB (top view)
Basic grid 2.54 mm
Terminal assignment
Relay - top view
Page 3 (11)
108-98007 Rev. C
D2n Relay
Coil Data (values at 23C)
Nominal voltage Unom Operate/set voltage range Minimum voltage Umin Vdc Vdc Maximum voltage Umax Vdc Vdc
V23105
Ordering Information
Release/ reset voltage Minimum Coil power Coil Resistance Relay code Tyco part number
mW
/ 10 %
150 mW nominal power consumption 5 6 9 12 24 4.0 4.8 7.2 9.6 19.2 11.7 14.0 21.0 28.0 56.0 0.25 0.30 0.45 0.60 1.20 150 150 150 150 165 167 240 540 960 3480 V23105A5001A201 V23105A5002A201 V23105A5006A201 V23105A5003A201 V23105A5005A201 8-1393792-5 8-1393792-7 9-1393792-1 8-1393792-8 9-1393792-0
200 mW nominal power consumption 3 5 6 9 12 24 48 2.1 3.5 4.2 6.3 8.4 16.8 33.6 6.1 10.1 12.2 18.2 24.3 48.6 97.2 0.15 0.25 0.30 0.45 0.60 1.20 2.40 200 200 200 200 200 200 200 45 125 180 405 720 2880 11520 V23105A5308A201 V23105A5301A201 V23105A5302A201 V23105A5306A201 V23105A5303A201 V23105A5305A201 V23105A5307A201 0-1393793-5 9-1393792-3 9-1393792-5 0-1393793-2 9-1393792-7 9-1393792-9 0-1393793-3
400 mW nominal power consumption 5 6 9 12 24 48 3.5 4.2 6.3 8.4 16.8 33.6 7.2 8.6 12.9 17.2 34.3 68.6 0.25 0.30 0.45 0.60 1.20 2.40 400 400 400 400 400 400 62 90 203 360 1440 5760 V23105A5401A201 V23105A5402A201 V23105A5406A201 V23105A5403A201 V23105A5405A201 V23105A5407A201 0-1393793-6 0-1393793-7 1-1393793-0 0-1393793-8 0-1393793-9 1-1393793-1
> 500 mW nominal power consumption 5 6 9 12 24 48 3.5 4.2 6.3 8.4 16.8 33.6 6.1 7.3 10.9 14.5 29.1 58.1 0.25 0.30 0.45 0.60 1.20 2.40 695 515 580 515 550 575 36 70 140 280 1050 4000 V23105A5501A201 V23105A5502A201 V23105A5506A201 V23105A5503A201 V23105A5505A201 V23105A5507A201 1-1393793-6 1-1393793-8 2-1393793-3 1-1393793-9 2-1393793-1 2-1393793-4
Coil versions, BT 47 type / specification T4563 C (current tested)
Nominal voltage Vdc 5 10 12 24 48 Operating current mA 80 32.5 27 14 7 Nominal power consumption mW 695 500 515 550 575 Resistance W / 10 % 36 200 280 1050 4000 47 W / 5 47 W / 9 47 W / 6 47 W / 7 47 W / 8 V23105A5475A201 V23105A5479A201 V23105A5476A201 V23105A5477A201 V23105A5478A201 1-1393793-2 3-1393794-0 1-1393793-3 1-1393793-4 1-1393793-5 British Telecom Code Relay code Tyco Part Number
Page 4 (11)
108-98007 Rev. C
D2n Relay
Coil operating range
3.0 2.8 2.6 2.4 2.2
V23105
150 mW coil 150 mW
3 2.8 2.6 2.4 2.2
200 mW coil 200 mW
Umax. at 0 A Umax. at 2 x 1 A Umax. at 2 x 2 A Coil Voltage [U/Unom]
Umax. at 0 A Umax. at 2 x 1 A Umax. at 2 x 2 A
Coil Voltage [U/Unom]
2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
2 1.8 1.6 1.4 1.2 1 0.8
Unom. nominal coil voltage
Unom. nominal coil voltage
Uop. min. Urel. min.
0.6 0.4 0.2 0 -30 -20 -10 0 10 20 30 40 50 60 70 80
Uop. min. Urel. min.
90 100 110 120
Ambient Temperature [C]
3.0 2.8 2.6 2.4 2.2
400 mW coil 400 mW
Ambient Temperature [C]
3.0 2.8 2.6 2.4 2.2
550 mW coil 550 mW
Umax. at 0 A Umax. at 2 x 1 A Umax. at 2 x 2 A Coil Voltage [U/Unom] Unom. nominal coil voltage
Umax. at 0 A Umax. at 2 x 1 A Umax. at 2 x 2 A Unom. nominal coil voltage
Coil Voltage [U/Unom]
2.0 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0
2.0 1.8 1.6 1.4 1.2 1.0 0.8
Uop. min. Urel. min.
-30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120
0.6 0.4 0.2 0.0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90
Uop. min. Urel. min.
100 110 120
Ambient Temperature [C]
Ambient Temperature [C]
Unom = Umax. =
Nominal coil voltage Upper limit of the operative range of the coil voltage (limiting voltage) when coils are continously energized Lower limit of the operative range of the coil voltage (reliable operate voltage) Lower limit of the operative range of the coil voltage (reliable release voltage)
Uop. min. = Urel. min. =
Page 5 (11)
108-98007 Rev. C
D2n Relay
Ordering Code
V23105
V23105
D2n Relay Identification
A5
A201
Version 0 = 150 mW nominal power consumption 3 = 200 mW 4 = 400 mW 5 = 550 mW Coil number 08 = 3 V nominal voltage (only with 150/200 mW nominal coil power consumption*) 01 = 5 V nominal voltage 02 = 6 V 06 = 9 V 04 = 10 V (only with 500 mW nominal coil power consumption) 03 = 12 V 05 = 24 V 07 = 48 V (not with 150 mW nominal coil power consumption) BT 47 versions 475 = 5 V nominal voltage 479 = 10 V 476 = 12 V 477 = 24 V 478 = 48 V Contact assembly A201 = 2 changeover contacts; silver nickel, gold-plated, against silver nickel, gold-plated
*) Coils with 400/500 mW nominal power consumption on request Ordering example: V23105-A5301-A201 D2 Relay, coil 5 V nominal voltage, 200 mW nominal power consumption, Contact material silver nickel, gold-plated, against silver nickel, gold plated
Page 6 (11)
108-98007 Rev. C
D2n Relay
Contact Data
Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage
V23105
Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance / measuring condition: 10 mA / 20 mV Electrical endurance at 230 Vac / 0.5 A at 6 Vdc / 0.1 A at 30 Vdc / 1 A at 30 Vdc / 2 A Mechanical endurance UL contact ratings
2 changeover contacts single contacts Silver-nickel, gold-covered 3A 3A 220 Vdc 250 Vac 60 W, 125 VA > 10 mV 100 mV < 100 mW typ. 3.0 x 105operations typ. 2.0 x 106 operations typ. 5.0 x 105 operations typ. 1.0 x 105 operations typ. 15.0 x 106 operations 30 Vdc / 1.0 A 100 Vdc / 0.3 A 125 Vac / 0.5 A for 150 mW and 200 mW coil 125 Vac / 1.0 A for 400 mW and 500 mW coil
Max. DC load breaking capacity
DC Voltage [Vdc]
DC current [A]
Page 7 (11)
108-98007 Rev. C
D2n Relay
Insulation
Insulation resistance at 500 Vdc Dielectric test voltage (1 min) between coil and contacts between adjacent contact sets between open contacts Surge voltage resistance according to FCC 68 (10 / 160 ms) between coil and contacts between adjacent contact sets between open contacts
V23105
> 109 W 1000 Vrms 750 Vrms 750 Vrms
1500 V 1500 V 1500 V
High Frequency Data
Capacitance between coil and contacts between adjacent contact sets between open contacts RF Characteristics Isolation at 100 / 900 MHz Insertion loss at 100 / 900 MHz V.S.W.R. at 100 / 900 MHz max. 2 pF max. 1.5 pF max. 1 pF
-39.0 dB / -20.7 dB -0.02 dB / -0.27 dB 1.04 / 1.40
General data
Operate time at Unom typ. / max. Release time without diode in parallel, typ. / max. Release time with diode in parallel, typ. / max. Bounce time at closing contact, typ. / max. Maximum switching rate without load Ambient temperature 150 and 200 mW coil 400 mW coil 500 mW coil Thermal resistance Maximum permissible coil temperature Vibration resistance (function) Shock resistance, half sinus, 11 ms Degree of protection / Environmental protection Needle flame test Mounting position Processing information Weight (mass) Terminal coating Resistance to soldering heat All data refers to 23 C unless otherwise specified. 5 ms / 7 ms 4 ms / 6 ms 7 ms / 10 ms 3 ms / 5 ms 20 operations/s -25 C ... +85 C -25 C ... +75 C -25 C ... +60 C < 100 K/W 105 C 10 g 10 to 55 Hz 10 g (function) 40 g (damage) immersion cleanable, IP 67 / RT III application time 20 s, burning time < 15 s any Ultrasonic cleaning is not recommended max. 2.5 g SnCu 0,7 260 C / 10 s
Page 8 (11)
108-98007 Rev. C
D2n Relay
Packing
Dimensions in mm
V23105
Tube for THT version - 25 relays per tube, 1000 relays per box
Page 9 (11)
108-98007 Rev. C
D2n Relay
IM Relays
V23105
D2n Relays
2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3 ... 48 V, coil power consumption from 150 .... 500 mW. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 20 x10 mm board space and 11,5 mm height.
4th generation slim line - low profile polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption of 140... 200 mW, latching relays with 1 coil 100 mW. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The IM relay is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height.
P1 Relays
P2 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 24 V, coil power consumption 65 mW, latching relays with 1 coil 30 mW. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version.
W11 Relays
FX Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FX2 is CECC/ IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height.
Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3 ... 24 V, coil power consumption 450 mW, sensitive versions 200 mW. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height.
Reed Relays
FT2 / FU2 Relays
High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc. Dimensions approx. 19,3 x 7 mm board space and 5 ... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version.
3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3 ... 48 V, coil power consumption 200 ... 300 mW. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) and FCC part 68 (1,5 kV - 10 / 160 s). The FT2/FU2 is CECC/IECQ approved and certified in accordance with IEC/EN 60950 and UL1950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height.
Cradle Relays
FP1 Relays
3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3 ... 48 V, coil power consumption of 80 ... 260 mW for the high sensitive version, 140... 300 mW for the standard version, latching relays with 1 coil 100 mW.. The FP1 Relay is available as through hole type and capable to switch loads up to 30 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kV - 10 / 160 s). The FP2 is CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height.
Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 Vdc to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height.
Other Relays
MT2 / MT4
We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 / V23031 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063 ... V23067 and V23163 ... V23167 series). Accessories like sockets, hold down springs, etc. optional.
2nd generation non polarized, non latching 2 c/o and 4 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 4.5 ... 48 V, coil power consumption 150/200/300/400 and 550 mW, and 300 mW (MT4). Dielectric strength fulfills the requirements according FCC part 68 (1,5 kV - 10 / 160 s) for both and the Bellcore requirements according GR 1089 (2,5 kV - 2 / 10 s) the MT4 only. Dimensions MT2 approx. 20 x 10 mm board space and 11 mm height, MT4 approx. 20 x15 mm board space and 11 mm height.
HF3 Relay
High performance low cost RF relay with excellent RF characteristics. Available with an impedance of 50 and 75 Ohm. Suitable for frequencies up to 3 GHz. Actually smallest RF relay available combining small size, excellent RF performance and SMD solderability. Available as non latching or latching relay with 1 or 2 coils and a nominal coil voltage range from 3 ... 24 V, coil power consumption 140 mW, latching relays with 1 coil 70 mW. Dimensions 14.6 x 7.3 x 10 mm.
Page 10 (11)
108-98007 Rev. C
Tyco Electronics AXICOM Ltd. Seestrasse 295 - P.O. Box 220 CH-8804 Au-Wadenswil / Switzerland Phone +41 1 782 9111 Fax +41 1 782 9080 E-mail: axicom@tycoelectronics.com
Tyco Electronics AMP GmbH Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38260 Fax +49 30 386 38569 E-mail: axicom@tycoelectronics.com
Tyco Electronics EC Trutnov s.r.o. Komenskeho 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com
Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752
Page 11 (11)
108-98007 Rev. C


▲Up To Search▲   

 
Price & Availability of V23105A5501A201

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X